FLUKE-115
Fluke®* Actual product may vary from image
Designed by electricians. Engineered by Fluke. For general purpose electrical and electronic test requirements, the Fluke 115 true-rms digital multimeter provides the perfect answer. Its simple operation, compact design and ease of use makes it perfect for quick verifications and field service use. The Fluke 115 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap. Fluke 115 multimeters are independently tested for safe use in CAT III 600V environments. And check out other members of the Fluke 110 family: the Fluke 113 Utility Multimeter, the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter and the Fluke 117 Commercial Electrician’s Multimeter. Also check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.
Details
MFG PART #:FLUKE-115
McMc Part #:FLUKFLUKE115
UPC #:095969324182
Inventory
$266.62 E
Details
MFG PART #:FLUKE-115
McMc Part #:FLUKFLUKE115
UPC #:095969324182
Inventory
Attributes
Features
Documentation
Attributes
Brand:Fluke®
Measuring Range:600 VDC/VAC, 10 A, 40 MOhm
Voltage Rating:600 VAC/VDC
Amperage Rating:10 A
Frequency Rating:5 Hz to 50 kHz
Resistance:0.1 Ohm to 40 MOhm
Safety Rating:CAT III 600 VAC/VDC
Capacitance:1000 uF
Accuracy:0.5% + 2 VAC
Display Type:Digital
Battery Type:9 VDC Alkaline/NEDA 1604A/IEC 6LR61
Peak Hold:No
Diode Test:Yes
Dimensions:1.81 in L x 3.35 in W x 6.58 in H
Temperature Rating:14 to 122 deg F
Material:Hard Plastic
Features
Large white LED backlight to work in poorly lit areas |
Resistance and continuity |
10 A AC/DC current measurement (20 A overload for 30 s max) |
Minimum maximum/average to record signal fluctuations |
2 deg pollution |
0.5% 2 VDC accuracy |
Resistance range - 600 Ohm with accuracy of +/-(0.9% 2), 6 kOhm, 60 kOhm, 600 kOhm, 6 MOhm with accuracy of +/-(0.9% 1), 40 MOhm with accuracy of +/-(1.5% 2) |
Capacitance range 1000 nF, 10 uF, 100 uF, 100 uF to 1000 uF with accuracy of +/-(1.9% 2), greater than 1000 uF with accuracy of +/-(5% 20) |
Frequency range 99.99 Hz, 999.9 Hz, 9.999 kHz, 50 kHz with accuracy of +/-(0.1% 2) |
400 hr typical alkaline, without backlight |